Measurement of thermal conductivity
- Temperature range from -125°C to 500°C
 - Heating/cooling rates from 0.01°C/min to 50°C/min
 - Measuring range thermal diffusivity from 0.01mm²/s to 1000mm²/s
 - Measuring range thermal conductivity from 0.1W/mK to 2000W/mK
 - Probe diameter: 10mm, 12.7mm or 25.4mm (each +/-0.2mm)
 - Sample thickness: depending on the thermal conductivity
Polymers: 0.05-3mm
Ceramics: 0.5-5mm
Metals: 1-5mm - Measurement of liquid samples possible
 
Measurement of calorimetric properties, e.g.
- reaction temperatures,
 - crystallization,
 - specific heat capacity,
 - melting processes,
 - thermal stability,
 - glass transition temperature,
 - oxidative induction time,
 - oxidative induction temperature.
 - Temperature range from -180°C to 700°C
 - Heating rate range from 0.001K/min to 200K/min
 - rapid cooling: max. 200K/min
 - gas-tight measuring cell
 - Gas control for 2 sample gases and 1 shielding gas via integrated mass flow controller and software
 - compressed air cooling from RT to 700°C
 - automatically controlled liquid nitrogen cooling from -180°C to 700°C
 
Measurement of the frequency-dependent magnetic properties of soft magnetic materials
- Samples in toroidal, round bar and sheet form
 - Measuring frequency range from 0.1Hz to 20kHz
 - Field strengths up to 120kA/m
 - Determination of remagnetization losses, coercive field strengths, magnetic polarizations, saturation polarizations, inductions, initial and maximum permeabilities, susceptibilities, remanences, new curves
 
Magnetization of hard magnets
- magnetizing voltage from 50V to 400V DC
 - Maximum field strength of 3500kA/m
 
Injection molding of thermoplastics
- 250kN clamping force
 - 20mm screw diameter
 - 31cm³ maximum stroke volume
 - 2350bar maximum injection pressure
 
Kneading and mixing of plastics, elastomers with particles, fibers, etc.
- Mixing volume 48cm³
 - Extruder operation possible with additional extruder attachment
 - maximum speed 250 min-1
 - maximum torque 160Nm
 - maximum temperature 400°C
 
Device for measuring magnetic induction in gauss, tesla or ammeter
- Measuring range from 0.01mT (0.1G or 0.01 kAm) to 2,999T (29.99kG or 2387kAm)
 - for measuring static direct and alternating fields
 - 3 measuring ranges
 
- Relative and absolute positioning of up to 3 stepper motors, zero point travel and virtual zero points
 - 3D interpolation and circular interpolation of 2 out of 3 axes
 - Positioning speed between 30 steps/s and 10000 steps/s
 - Value range of 24 bits
 - Maximum path resolution of +/- 8,000,000 steps
 